|
Promag 10W |
Promag 10P |
Promag 10H |
Magphant DTI200 |
Promag 50W |
Promag 50P |
Promag 50H |
Promag 53W |
Promag 53P |
Promag 53H |
Promag 23P |
Promag 23H |
Promag 51W |
Promag 51P |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Main features |
Flow measurement of liquids in water or waste water applications |
Flow measurement of liquids in auxilliary circulations or waste water applications |
Flow rate measurement of liquids in simple hygienic or food applications |
Electromagnetic flowmeter for flow monitoring by means of limit value setting |
Standard applications for flow rate measurement of fluids in water / waste water applications |
Standard applictaions for flow rate measurement in chemical or process applications |
Standard applications for flow rate measurement of fluids in hygienic / food or process applications |
For high requirements in flow rate measurement of liquids in water / waste water applications |
For high requirements in flow rate measurement of liquids in chemical or process applications |
For high requirements in flow rate measurement of fluids in hygienic / food or process applications |
Flow rate measurement of liquids in chemical or process applications
Especially suitable for use in the chemical industry in two-wire technology
Suitable for use in Ex- zones |
Flow rate measurement of liquids in hygienic / food or process applications
Especially suitable for use in the chemical industry in two-wire technology
Suitable for use in Ex-zones |
PTB certified for custody transfer with cold water |
PTB certified for custody transfer with cold water |
Diameter |
DN 25...600
1"...24" |
DN 25...300
1"...12" |
DN 2...100
1/12"...4" |
DN15...DN2000
1/2"...80" |
DN 25...2000
1"...78" |
DN 15...600
1/2"...24" |
DN 2...100
1/12"...4" |
DN 25...2000
1"...78" |
DN 15...600
1/2"...24" |
DN 2...100
1/12"...4" |
DN 25...200
25"...8" |
DN 2...100
1/12"...4" |
DN 25...2000
1"...78" |
DN 15...600
1/2"...24" |
Measuring range |
0...9'600 m3/h |
0...2'400 m3/h |
0...282 m3/h |
0...56'550 m3/h |
0...110'000 m3/h |
0...9'600 m3/h |
0...282 m3/h |
0...110'000 m3/h |
0...9'600 m3/h |
0...282 m3/h |
0...1100 m3/h |
0...282 m3/h |
0...110'000 m3/h |
0...9'600 m3/h |
Process temperature |
-20...+80°C |
-40...+130°C |
-20...+150°C |
-20...+120°C |
-20...+80°C |
-40...+180°C |
-20...+150°C |
-20...+80°C |
-40...+180°C |
-20...+150°C |
-40...+180°C |
-20...+150°C |
-20...+80°C |
-40...+150°C |
Pressure range |
PN10...40
Cl 150
JIS 10...20K
AS 2129 Table E |
PN10...40
Cl 150
JIS 10...20K
AS 2129 Table E |
PN16...40 |
0...16 bar abs |
PN6...40
Cl 150...300
JIS 10...20K
AWWA Class D
AS 2129 Table E |
PN10...40
Cl 150...300
JIS 10...20K
AS 2129 Table E |
PN16...40 |
PN6...40
Cl 150...300
JIS 10...20K
AWWA Class D
AS 2129 Table E |
PN10...40
Cl 150...3000
JIS 10...20K
AS 2129 Table E |
PN16...40 |
PN10...40
Cl 150...300
JIS 10...30 K |
PN16...40 |
PN6...40 |
PN10...40 |
Accuracy |
±0.5% |
±0.5% |
±0.5% |
2% |
±0.5%
±0.2% (optional) |
±0.5%
±0.2% (optional) |
±0.5%
±0.2% (optional) |
±0.2% |
±0.2% |
±0.2% |
±0.5% |
±0.5% |
±0.5%
±0.2% (optional) |
±0.5%
±0.2% (optional) |
Display/Operation |
Two line display
Push buttons |
Two line display
Push buttons |
Two line display
Push buttons |
Test function |
Two line display with backlit
Push button |
Two line display with backlit
Push button |
Two line display with backlit
Push button |
Four line display with backlit
Touch control |
Four line display with backlit
Touch control |
Four line display with backlit
Touch control |
Four line display
Touch control |
Four line display
Touch control |
Two line display with backlit
Push button |
Two line display with backlit
Push button |
Inputs |
|
|
|
- |
Status |
Status |
Status |
Status
Current input |
Status
Current input |
Status
Current input |
|
|
Status |
Status |
Outputs |
4...20mA
Pulse
Status |
4...20mA
Pulse
Status |
4...20mA
Pulse
Status |
4...20 mA
Relay |
4...20 mA
Pulse/Frequency
Status |
4...20 mA
Pulse/Frequency
Status |
4...20 mA
Pulse/Frequency
Status |
4...20 mA
Pulse/Frequency (active/passive)
Relays
Status |
4...20 mA
Pulse / frequenz (aktive/passive)
Relays
Status |
4...20 mA
Pulse / frequency(active/passive)
Relais
Status |
4...20 mA
, alternatively pulse, frequenzcy or status |
4...20mA, alternatively pulse, frequency or status |
4...20 mA
Pulse/Frequency
Status |
4...20 mA
Pulse/Frequency
Status |
Communication |
HART |
HART |
HART |
|
HART
Profibus PA |
HART
Profibus PA |
HART
Profibus PA |
HART
Profibus PA
Profibus DP
Foundation Fieldbus |
HART
Profibus PA
Profibus DP
Foundation Fieldbus |
HART
Profibus PA
Profibus DP
Foundation Fieldbus |
HART |
HART |
HART |
HART |
Ex-Approvals |
FM
CSA |
FM
CSA |
FM
CSA |
FM
CSA |
ATEX
FM
CSA |
ATEX
FM
CSA
TIIS |
ATEX
FM
CSA
TIIS |
ATEX
FM
CSA |
ATEX
FM
CSA
TIIS |
ATEX
FM
CSA
TIIS |
ATEX
FM
CSA |
ATEX
FM
CSA |
ATEX |
ATEX |
Protection electronic |
IP 67 (Nema 4x)
IP 68 (Nema 6P) |
IP 67 (Nema 4x)
IP 68 (Nema 6P) |
IP 67 (Nema 4x) |
IP 66
NEMA 4x
Type 4X |
IP 67 (NEMA 4x)
IP 68 (Nema 6P) |
IP 67 (NEMA 4x)
IP 68 (Nema 6P) |
IP 67 (NEMA 4x) |
IP 67 (NEMA 4x)
IP 68 (Nema 6P) |
IP 67 (NEMA 4x)
IP 68 (Nema 6P) |
IP 67 (NEMA 4x) |
IP 67 (NEMA 4x) |
IP 67 (NEMA 4x) |
IP 67 (NEMA 4x)
IP 68 (Nema 6P) |
IP 67 (NEMA 4x)
IP 68 (Nema 6P) |
Features |
Monitoring of the medium
Bullet nose electrodes |
Monitoring of the medium
Bullet nose electrodes |
Monitoring of the medium
3A authorization and EHEDG-tested |
A compact device for all applications |
S-DAT
Validation
Quick Set-Up
Monitoring of the medium
ECC
2 Totalizer
Bullet nose electrodes |
S-DAT
Validation
Quick Set-Up
Monitoring of the medium
ECC
2 Totalizer
Bullet nose electrodes |
S-DAT
Validation
Quick Set-Up
Monitoring of the medium
ECC
2 Totalizer
3A authorization and EHEDG-tested |
S-DAT, T-DAT F-CHIP
Validation
Quick-Set-Up
ECC
3 totalizers
Bullet nose electrodes
Bi-directional totalizer
Pulsating flow
Density function
Mass calculation
Dosage |
S-DAT, T-DAT, F- CHIP
Validation
Quick Set-Up
ECC
3 totalizers
Bullet nose electrodes
Bi-directional totalizer
Pulsating flow
Density function
Mass calculation
Dosage |
S-DAT, T-DAT, F- CHIP
Validation
Quick Set-Up
ECC
3 totalizers
Bi-directional totalizer
Pulsating flow
Density function
Mass calculation
Dosage
3A authorization and EHEDG-tested |
Two-wire MID
Intrinsically safe
For standard applications
S-DAT, T-DAT
Validation
2 Totalizers
Density function
Mass calculation |
Two-wire MID
Intrinsically safe
For standard applications
S-DAT, T-DAT
Validation
2 Totalizers
Density function
Mass calculation
3A authorization and EHEDG-tested |
S-DAT
Validation
Quick Set-Up
ECC
2 Totalizer
Bullet nose electrodes
PTB cold water approval |
S-DAT
Validation
Quick Set-Up
ECC
2 Totalizer
Bullet nose electrodes
PTB cold water approval |
Advantages |
Ideal for simple measuring tasks
Current output displays current flow, pulse output as a status output
Service-friendly, functional design, simplified maintenance
Guaranteed safety of the application
Opeartion under extreme conditions (in shafts, vibrations or when permanetly under water) - the sensor van be installed separately from the transmitter and is available in the degree of protection IP 68. |
Guaranteed saftey of the application
Service-friendly, functional design, simplified maintenance
Maximum resistance with aggressive media guaranteed with the PFTE lining
Operation under extreme conditions (in shafts, vibrations or when permanently under water) - the sensor can be installed separately from the measuring transmitter and is available in the degree of protection number IP 68. |
Guaranteed saftey of the application
Servive-friendly, functional design, simplified maintenance
Guaranteed high bacteriological safety
Maximum resistance with aggressive media guaranteed with the PFA lining
Stainless steel sensor
Piggable sensor |
Flow monitoring by means of limit value setting
Self-monitoring measuring system
Integrated test function to test the functionality of the electronics |
Easy servicing and maintenance. Validation on site without removal of the sensor:
- Optimized plant maintenance
- Incorporation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
"Quick Setup" menus for straightforward commissioning in the field |
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
"Quick Setup" menus for straightforward commissioning in the field |
Guaranteed product quality, because the product is CIP-/SIP cleanable and piggable
Stainless steel housing for high sanitary safety
Robust field housing in IP 67
IP 67 wall-mount housing for straightforward installation of the remote version
"Quick Setup" menus for straighforward commissioning in the field |
Easy servicing and maintenance. Validation possible on site without removal of the transmitter:
- Optimized plant maintenance
- Incorporation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
with "Touch Control": operation from outside without opening the housing.
"Quick Set-Up" menus for straightforward commissioning in the field |
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
with "Touch Control": operation from outside without opening the housing
Software package may be updated for:
- Dosage applications
- Electrode cleaning
- Increased operational safety
"Quick Setup" menus for straightforward commissioning in the field |
Guaranteed product quality because the product is CIP-/SIP cleanable and piggable
Stainless steel housing for high sanitary safety
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
with "Touch Control": Operation from outside without opening the housing
Software packages may be updated:
- for dosage applications
- fur increased operational safety
"Quick Setup" menus for straightforward commissioning in the field |
High measurement value stability, not affected by the flow rate
Reduced installation and operation costs
Robust field housing in IP 67 with seperate terminal compartment
"Touch Control": operation without opening the housing, also in Ex- environment
Connection to all mainstream transmitter power supplies and input cards of process systems |
Guaranteed product quality because product is CIP-/SIP cleanable and piggable
Robust field housing IP 67
"Touch Control": operation without opening the housing, also in Ex- environment
Connection to all mainstream power supplies and input cards of process control systems
Reduced installation and operation costs
High measurement value stability, not affected by the flow rate |
With national type examination for cold water(GER)
Fitting lengths to DVGW und ISO standards
Easy servicing and maintenance. Validation on site possible without the removal of the sensor:
- Optimized plant maintenance
- Incorporation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straighforward installation of the remote version
"Quick Setup" menu for straightforward commissioning in the field
Operation under extreme conditions
- The sensor can be installed separately from the transmitter and is available in the IP 68 protection form. |
With national type examination for cold water (GER)
Fitting lengths to DVGW and ISO standards
Easy servicing and maintenance. Validation possible on site without removal of the sensor:
- Optimized plant maintenance
- Incorportation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
"Quick Setup" menu for straightforward commissioning in the field
Operation under extreme conditions
- The sensor may be installed separately from the transmitter and is available in the protection form IP68. |